Energy baseline
Fixed fee.
- Rules check per site
- 30 days of measurement
- Baseline and load-profile report
- Fee credited when you subscribe
With the new Flemish energy efficiency rules, the audit duty drops to 10 TJ per site, sites report their energy use every year, and larger users need an energy management system. We install the measurement, deliver the figures your auditor and VEKA ask for, and turn them into savings, as a service.
This runs on measured data. There are three ways to get it, and only the third involves buying anything from us.
A historian, SCADA, submeters, your own exports — often more than people expect.
Your machine builder's, your energy supplier's, your grid operator's.
When neither exists, we install the measurement and run it as a service.
Not used
Combined with your quarter-hour data from Fluvius, with your consent. Nothing passes through your network.
| Energy audit | From 10 TJ (about 2.8 GWh) per site: an audit; below 50 TJ, measures with a payback under three years carried out within three years | 1 Jul 2027 |
| Annual energy reporting | From 10 TJ: energy use per carrier and application, reported to VEKA | Yearly |
| Energy management system | Above 85 TJ (about 23.6 GWh): a certified system such as ISO 50001 | 11 Oct 2027 |
| Energy plan | From 100 TJ: a verified energy plan | 1 Oct 2027 |
| Building automation (GACS) | Non-residential buildings with heating or cooling above 290 kW: monitor, record and analyse energy use continuously. By end 2029 above 70 kW | Since end 2025 |
Sources: Flemish government, building automation obligation for non-residential buildings; draft Flemish decree transposing the revised EED, approved in principle on 17 July 2026 (Voka; final text still to be adopted). Thresholds apply per site, on the average yearly energy use. We deliver the measured data and reports; the audit, certification and building control stay with your auditor, certifier and installer.
Which rules apply to each site, based on your energy use and installations.
Meters on the main connection and the largest users, installed de-energised.
Energy use and load profiles for working and non-working days.
The figures your auditor, certifier or regulator asks for.
Savings measures and their effect, followed month by month.
Fixed fee.
Per measuring point, per month.
Added when you need them.
Sites around 10 TJ, facing the audit and yearly reporting.
Sites above 85 TJ, preparing an energy management system.
Heated or cooled buildings above 290 kW.
Start with a free 30-minute call, with last year’s energy bills at hand.
If your site sits well under the audit thresholds and your energy bill is not a board-level number, measurement is a cost without a return yet. The honest first step is then the grid data you can already request for nothing, and a conversation in a year.